LA-950V2 |
 |
|
Overview
Product Overview
The
Partica LA-950V2 Laser Diffraction Particle Size Analysis System is the
second generation of the revolutionary LA-950 system, retaining the
unparalleled measurement performance of the previous version with a
number of usability and sampling system upgrades.
The result is a truly unparalleled system for particle size analysis for a wide range of user requirements.
A
thorough redesign of a number of components has enhanced the
class-leading capabilities in speed, dynamic range, accuracy, and
precision. At the same time, a number of customer requests have been
incorporated into the system design to make the sample system change
even faster, improve sampling system accessibility, and broaden the
range of accessories available.
The Partica LA-950V2 particle
size analyzer is available in a number of different versions to
optimize the system for specific user requirements.
Product Features
The Partica LA-950V2 provides a number of unparalleled features:
Widest Measurement Range Available: HORIBA’s
revolutionary optical system design provides the widest dynamic range
(0.01-3000µm), while still offering the lowest detection limit and best
small-size performance of any laser diffraction instrument. The long
focal length also makes possible the best large-particle performance
available.
Unequaled Accuracy, Precision, and Reproducibility - Guaranteed: The
highly refined optical system, combined with improved components and an
optimized algorithm, provide provide unmatched accuracy, precision and
resolution. - Accuracy guaranteed to within 0.6%
- Precision guaranteed to within 0.1%
- Stability and reproducibility from unit to unit ensured with rigid optics and detector calibration
Software Features
Customizable setting of data displays, graphics, sizing, client logos, print and onscreen report formats available to user.
Database data storage with batch operation and
multiple search criteria. Searchable database included that is easy to
use and on which any saved sample criteria or identification may be
used as a search algorithm.
Software wizard to build easy to use macros and
save them as product specific files. All operations of both sample and
condition files can be incorporated into a macro for repeated use. User
has available an unlimited number of macros that can be saved.
Self-maintenance and automatic system checking software
Fastest Sample-To-Sample Measurement Time - 60 Seconds: Automation
built into the hardware and software ensures speed, reproducibility and
ease of use. Complete sample analysis sequence is completed in 60
seconds, including fill, alignment, blank, measurement, drain and rinse
cycles.
Watch the video to see it for yourself!
Most Powerful Sampling Systems Available: The
modular design allows for a range of sample dispersion systems to be
offered to optimize the analyzer system for the end user's
requirements. Each system has been improved over successive generations
to include the features required in modern particle size analysis.
The standard high-output centrifugal pump, capable
of suspending even the largest dense particles includes a powerful
inline ultrasonic probe for dispersion of agglomerates and a standard
fill pump to automate the analysis sequence. This allows the complete
sample dispersion and analysis sequence to be handled without the need
for external sample preparation.
Alternative sample systems are available in
different volumes, for organic solvents, and with different pump types
for specific applications.
Fastest Sampling System Change: The unique
measurement cell system allows up to three sample dispersion systems to
be mounted simultaneously on a cell tray. Changing between sampling
systems only requires the tray to be moved from one position to
another, in as little as ten seconds, without removing or replacing any
hardware.
Alternative designs require removal of one sampling
systems and replacement with the next, requiring extra storage space
and need to remove cell, connect tubing, electronic changes, add dry
system, align components, etc.
Watch the video to see it for yourself! |
 |
Specifications
Product Specifications
The
LA-950V2 family of analyzers can be configured for a variety of sample
analysis types with a range of sample handling systems and options. A
full range of wet and dry sampling systems are available to optimize
the system for specific user requirements.
AquaFlow: The standard high-output
centrifugal pump suspends and circulates even the largest dense
particles without crushing particles or wearing tubes. The in-stream,
adjustable-power, 130 watt ultrasonic probe has offers the highest
dispersing efficiency and the built-in fill pump and ultrasonic level
sensor completely automated the sampling sequence.
SolvoFlow: All the features of the AquaFlow pump, with resistance to organic solvents.
PowderJet Dry Feeder: For
powdered materials, the PowderJet Dry Feeder system provides a simple,
yet effective, method for analyzing both free-flowing and cohesive dry
powders.
Automatic control of sample feed rate provides
optimum dispersion, stability and ease of use. The adjustable power
dispersion nozzle allows for measurements of all sample types from
friable crystals to highly cohesive agglomerates.
See our PowderJet page for more details.
MiniFlow small volume: The MiniFlow is a
small volume circulation system; minimizing sample and dispersant
volume requirements with all the convenience of a fully automated
circulation system. It features a variable 35 to 55 ml volume
requirement, resistance to organic solvents, a built-in ultrasonic
probe for dispersing highly agglomerated materials, automatic fill pump
with level sensors, and automatic fill pump with level sensors, and
automatic drain system.
The
MiniFlow is ideal for measuring very precious samples, samples that are
toxic or hazardous, where the waste volume wants to be minimized, for
pharmaceutical or food applications requiring organic solvent
dispersants, or oil dispersions for pigments, polymers and resin
products.
Fraction Cell / Holder: The cuvette-type
Fraction Cell allows liquid suspensions as small as 10 ml to be
measured, making it perfect for measuring very valuable, extremely
small, or hazardous samples.
Automation Options: Adding automation
accessories provides all the advantages of continuous, unattended
operation including reduced labor costs, elimination of human error,
and exceptionally reliable, repeatable measurements. See our Automation page for more details.
Principle of Operation
The
Partica LA-950 uses Mie Scattering Theory (laser diffraction) to
measure particle size over the range of 0.01-3000µm. The optical design
of the Partica is optimized for light-scattering measurements, with an
87element logarithmic detector system and automatic alignment, together
with the shortest wavelength light sources available to provide
full-range measurements and the ultimate in sub-micron accuracy and
resolution. The advanced design avoids the long optical bench
previously required to measure larger particles, without combining
multiple analysis methods in one measurement or giving up capabilities
in the sub-micron range. For information on laser diffraction, visit
our technique page.
|
|
 |
LA-300 |
 |
| |
Overview
Product Overview
HORIBA's
LA-300 Laser Diffraction Particle Size Distribution Analyzer is the
ideal combination of performance, price, and packaging. Based on the
advanced optical design of previous LA-series analyzers, the LA-300
strikes a harmonious balance between high-functionality, easy
operation, low maintenance, and cost-effectiveness. The optimized
design allows for a compact optical bench, resulting in an efficient
use of bench space, while preserving the accuracy, precision and
resolution that HORIBA's analyzers are famous for.
Product Features
- Range: 0.1 - 600µm Matching the widest range of applications with a performance equivalent to most competitors' full range systems.
- Compact Size:
The compact size and low weight make this a convenient analyzer for
today´s crowded laboratories. It also makes it possible to transport
easily to different locations within a facility or ship to remote
locations for on-site testing where it is not practical to purchase an
analyzer.
- Fast Analysis: The highly-refined optical
design and algorithm provides measurement results in 20 seconds, with
class-leading accuracy and precision.
- Powerful Software:
The LA-300 uses the same fully featured software package as our other
LA-series analyzers, providing a wide range of statistical measures,
data analysis, and presentation tools.
- Ease of Use: With
automatic alignment, built-in ultrasonic system for sample dispersion,
and powerful pumping system, combined with the automation features of
the software, sample analysis on the LA-300 is extremely easy and
straightforward. Combined with the automation options, sample analysis
can be a one-button operation.
|
 |
Specifications
Product Specifications
- Size range: 0.1-600µm
- Measurement time:
Adjustable in one second increments. Sample measurement time is less
than 2 minutes from the introduction of sample to data presentation
- Sample requirement:10mg to 1g per measurement with 300ml flow cell, depending on sample type.
- Ultrasonic working time: 0-30 minutes with 1.0 second measurement increments (15W, 28KHz).
- Circulation rate: 0-5,500 ml/min (in case of distilled water), and a 15 step selection.
Principle of Operation
The LA-300 uses Mie Scattering Theory (laser
diffraction) to measure particle size over the range of 0.1-600µm. A
650nm solid-state, diode laser is focused by an automatic alignment
system through the measurement cell. Light is scattered by the
particles to a 42-element detector system, including high-angle and
back-scatter detectors for a full angular light intensity distribution.
The thick, cast-aluminum optical bench provides stable, high-precision
results. For more information on laser diffraction, visit our Laser Diffraction Technique page.
Accessories
Automation: For complete automation of the sample
analysis sequence, the Slurry Sampler can accommodate up to 60 samples.
Set up the samples and walk away. An AutoFill pump is available to
automate the dispersant fluid filling, dilution, and rinsing steps.
Adding automation accessories provides all the advantages of
continuous, non-stop, unattended operation. These include reduced labor
costs, elimination of human error, and exceptionally reliable,
repeatable measurements. Visit our Automation Page for more information.
Fraction Cell/Holder: The
cuvette-type Fraction Cell allows liquid suspensions as small as 5 ml
to be measured, making it is perfect for measuring very valuable or
extremely small or hazardous samples.
Pharmaceutical Regulation Compliance: A 21CFR Part 11 compliant software package is available, as well as a full instrument validation package. |
|
 |
LB-550 |
 |
| |
Overview
Product Overview
The
LB-550 measures particle size from 1nm to 6µm and a concentration range
from ppm up to 40% solids, all in as little as 30 seconds, making it
ideally suited to a wide range of applications. Unlike traditional
PCS-type instruments, most samples can be measured without dilution
which can affect dispersion conditions and cause agglomeration.
With a standard analysis time of on to two minutes,
the LB-550 is the fastest and most flexible particle size analyzer for
the nanometer range of sizes. The Fourier-Transform/Iterative
Deconvolution technique provides accurate results not only for average
particle size, but also for distribution shape and identification of
multiple modes, all without operator selections, a feature not found in
most Photon Correlation Spectroscopy (PCS) instruments. Elimination of
the need to select from alternative models and evaluating fitting
errors provides confidence in the results and faster data analysis.
The temperature-controlled cell holder has a range
of 5-70 degrees C for samples where size may change with temperature.
Standard removable glass or disposable plastic curvettes are used to
eliminate sample cross-contamination, ease cleaning and improve
usability. Cells are available for sample volumes from 0.1-15ml. For
high concentration samples where viscosity may affect results, a
built-in viscometer option is available to provide accurate
measurements at the time of analysis. Product Features
- Wide Size Range: Accurate particle size measurements from 0.001-6µm.
- Fast Analysis:
The highly-refined optical design and algorithm provides measurement
results in as little as 30 seconds, with class-leading accuracy and
precision.
- Wide Concentration Range: From 1ppm to 40wt%, depending on the sample.
- Powerful Software:
The LB-550 software package combines a number of useful data handling
tools, and easy-to-use operator interface, and informative instrument
control features. A Real-Time Display, batch operations, database
searching, three-dimensional display of up to 300 measurement results,
and summary reports allow for full control and analysis of the data.
The user interface, print layout, and export functions are fully
user-configured to provide the specific information required by each
user.
- Temperature Control System: Temperature Control
System : The temperature-controlled cell holder has a range of 5-70
degrees C for samples where size may change with temperature.
Temperature sensors in the cell holder and in the cell cap monitor and
control the temperature to avoid fluctuations.
- Ease of Use:
With the built-in automation of the sampling systems and software,
particle size analysis can be reduced to a single-button operation.
|
 |
Specifications
Product Specifications
Principle of Operation
The LB-550 uses Dynamic Light Scattering
measurements to measure particle size over the range of 0.001-6µm. The
Brownian motion of the particles causes a Doppler shift in the incident
light frequency. The amount of frequency shift is related to the
frequency of the Brownian motion, wich is related to the size of the
particles.
The LB-550's optical design uses a highly sensitive
photo multiplier tube to be able to measure the lower concentrations.
The optical arrangement which captures only the 180-degree scattered
light, allows the light beam to be focused a short distance inside the
cell, limiting the maximum amount of scattered light. This allows the
measurement of high concentration samples without overloading the
detector For more information on dynamic light scattering, visit our technique page.
Accessories
Integrated Viscometer Version: For unknown
samples, an integrated viscometer version is available to directly
measure and compensate for variations in viscosity which can
significantly affect the measurement results.
Pharmaceutical Regulation Compliance: A 21CFR part 11 compliant software package is available, as well as a full instrument validation package. |
|
| |
|
|