With over 30 years of design expertise
in Laser Particle Size Analyzers, CILAS offers a wide
range of products designed with your specific application
in mind. Choose the model that best covers your range
of particles. Regardless of which model you select,
rest assured that all of our accessories and options
are available. Even our most cost-effective model supports
our autosampler, video accessory and short optical bench.
All CILAS particle size analyzers offer our unique
integrated wet and dry dispersion mode design. This
allows the operator to switch between wet and dry modes
through our software.
High-resolution detectors are used for the sampling
of the diffraction pattern and provide you exact and
reproducible results through Fraunhofer and Mie algorithms.
This guaranties you full compliance with the ISO 13320
standard. |
 |
The
Short Bench Concept is a unique feature developed
by CILAS. Our patented design has all the optical
components rigidly aligned on a short cast iron
baseplate. Permanently aligned optics guarantee
the system is aligned throughout the entire measurement,
providing more reliable particle size distribution
data. |
 |
2 in 1 integrated
wet and dry dispersion modes. CILAS unique design
provides very fast measurements in wet or dry mode.
The system can be configured to measure in wet or
dry mode with just the click of a mouse. Only CILAS
lets you switch modes without swapping hardware. |
 |
Our intuitive
software allows you to drive the instrument with
just the click of the mouse on the interactive graphic
screen. Simply click on a picture of the component
you want to turn on or off and the software makes
the change for you. No need to search through menus
to find the feature you need. |
 |
Perform particle shape and size
analysis with our integrated video camera. CILAS
has the only Laser Particle Size Analyzer which
can show you the shape of your particles while performing
particle size distribution analysis. |
|
|
| |
| Principal of measurement |
Laser
diffraction - Based on Mie and Fraunhofer sacttering
theories |
| Operating specifications |
Ecosizer |
930e |
1064 |
1180 |
| Size range
(µm) |
0.5 - 400 |
0.2 - 500 |
0.04 - 500 |
0.04 - 2500 |
| Liquid/Dry
Mode |
L/D |
L/D |
L/D |
L/D |
|
| Data Accquisition
Time |
30 sec |
30 sec |
30 sec |
30 sec |
|
| Amount of sample required |
< 5gm |
< 5gm |
< 5gm |
< 5gm |
|
 |
Features |
 |
High resolution with new designed
detectors |
 |
Short bench : 40 cm, no realignment
required |
 |
Easy for use and maintainance |
 |
Compliant to ISO 13320 Norm |
 |
Compact, robust |
 |
Advanced and fast SOPS mangement |
 |
Powerful custom report facilites |
 |
Easy and intuitive display functions |
 |
HTML, Excel files generation |
 |
CFR 21 Part 11 compliance |
|
|
| [
-- Back to Top --] |
| |
| The Ecosizer |
| Principle of Measurement |
With an extremely compact cast iron optical bench,
the CILAS EcoSizer is able to run powder or emulsion size
analysis. from 0.5 up to 400 µm, within a few seconds.
The 830 nm laser diode, with a very long lifetime, lights
the sample. A photodiode matrix detector acquires the
diffraction pattern. |
 |
|
 |
Compact rapid |
 |
Best ratio Performance/Price |
 |
Mie |
 |
Economic apparatus with a full option software |
 |
The most rugged instrument for routine analysis
even in hostile industrial environment |
|
Non contractual Document
- 4/2005
All the information and specifications of the particle
size analyzers are subject ot change without notice by
CILAS. |
| |
|
| [
-- Back to Top --] |
| The
CILAS 930 gives you the best price/performance
ratio of any system on the market. You can measure particles
with size ranging from 0.2 to 500 µm. All of our
more advanced, time saving options and accessories are
available for the 930. These include an autosampler,
video camera for performing shape analysis, integrated
wet and dry dispersion modes and our powerful Size Expert. |
 |
| |
Ideal for process control |
 |
| The CILAS 930 has been
designed for performance and reliability. It quickly
and easily performs particle size analysis for particles
from 0.2 to 500µm. The 930e is the system
of choice for all the fields of applications from
cement to pharmaceutical. |
|
Simple yet powerful |
 |
| The instrument and its software are
very easy to use. Make measurements or change the
system configuration with just the click of a mouse
using our intuitive software. For repetitive testing,
boost your productivity by creating a standard operating
procedure. |
|
Change from wet to dry mode in 1 second |
 |
| The transition from wet to dry mode
is accomplished in the software with one click of
the mouse. Our unique design eliminates the need
for the operator to swap hardware when switching
modes. |
|
Exceptional reliability |
 |
| We have eliminated movable mechanical
parts and exposed optical components to create the
most reliable system on the market. Our one-piece
design ensures results which are very accurate and
reproducible. The CILAS 930e can be used for intensive
measurements in aggressive industrial environments. |
|
Compliant with ISO 13320 and 21 CFR–Part11
|
 |
| The 930 is compliant with the ISO
13320 standard for particle size analyzers as well
as the 21 CFR-Part 11. |
|
|
| [
-- Back to Top --] |
| The 1064 is a mid-range
instrument offering a wider range of particle size measurements.
With two lasers and CILAS multi-wavelength optical architecture,
this instrument gives you a measurement range from 0.04
to 500 µm in wet or dry mode. |
 |
 |
 |
 |
 |
| Short Bench Concept |
Integrated wet and dry dispersion modes
|
Interactive graphical software |
|
|
|
| |
| |
Dual wavelength architecture |
 |
| The 1064 uses two lasers
in order to cover a wider range of particle sizes.
CILAS unique design places the second laser at a
45 degree angle to extend the range without increasing
the size of the instrument. |
|
Permanently aligned optical system |
 |
| All optical components are fixed
on a cast iron baseplate. There is no need to realign
the system or change the lens during or between
acquisitions as done in competitive systems. Our
permanently aligned optics guarantees extremely
accurate and reproducible particle size measurements. |
|
right choice for laboratory and research applications |
 |
| This mid-range instrument is focused
on laboratory and industrial applications where
very small to medium size particle analysis is required. |
|
Integrated dispersion systems with fast change from
wet to dry mode |
 |
| There is no need to swap hardware
when switching from wet to dry mode. The change
can be made in software with just the click of a
mouse. |
|
Compliant with ISO 13320 and 21 CFR Part 11 |
 |
| All CILAS systems comply with the
ISO 13320 standard for particle size analyzers and
with 21 CFR-Part 11 for pharmaceutical applications. |
|
|
| [
-- Back to Top --] |
| The CILAS 1180 sets a
new standard in particle characterization. Its integrated
wet and dry dispersion modes, built in video camera and
short optical path make it the most versatile instrument
available anywhere. The unique design of the 1180 provides
a measurement range from 0.04 to 2,500µm while maintaining
an extremely small footprint. |
| |
| |
Permanently aligned optical system
|
 |
| Our background in the
aerospace industry gives us the technical know-how
to develop an extremely rugged system. The 1180
has all optical components permanently mounted on
a rigid cast iron baseplate. This design eliminates
the need to ever realign the system, thus ensuring
the highest level of performance. |
|
Short bench concept |
 |
| The integration of a CCD camera offers
customers the ability to measure an extended range
of samples while maintaining a short bench design.
This unique design provides for a more rugged and
reliable analysis tool. The short bench concept
allows CILAS to significantly extend the measurement
range without increasing the size of the instrument. |
|
View
particle shape along with particle size |
 |
| Adding a CCD camera allows the CILAS
1180 to gather particle shape information along
with the traditional particle size distribution
data. Our Particle Expert software includes extended
calculation models for the shape characterization
of your product. |

Shape Analysis using a CCD camera |
|
Integrated wet and dry mode |
 |
| Change from wet to dry mode in software
with just the click of the mouse. Our innovative
design eliminates the need for the operator to swap
hardware when switching modes. |
|
Free fall module |
 |
| The 1180 includes a free fall module
for customers wishing to analyze samples in their
naturally agglomerated state. |
|
Compliant with ISO 13320 and 21 CFR–Part11
|
 |
| The 1180 is compliant with the ISO
13320 standard for particle size analyzers as well
as the 21 CFR-Part 11. |
|
| |
|
THE SIZE EXPERT SOFTWARE |
| The Size Expert benefits : |
|
 |
Interactive, user-friendly software |
 |
Advanced tools for data management, statistical
analysis, and report generation |
 |
Standard Operation Protocol implementation |
 |
Shape analysis |
 |
ISO 13320-1 and 21
CFR-11 Compliant. |
|
|
| |
| INTUITIVE CONCEPT |
| "The Size Expert"
software drives all CILAS particle size analyzers
with an interactive graphical display. Our intuitive,
user-friendly software makes it easy to control
system operation and perform calculations. The interactive
graphical display shows a symbolic representation
of the different particle size analysis functions,
including the laser, ultrasound, pumps (wet mode)
and vibratory feeder (dry mode). Simply click on
one of these symbols to turn that portion of the
analyzer on or off. All calculation capabilities
are easily accessible in pull-down menus. |
|
|
| |
| SHAPE ANALYSIS
|
| With the release of new Particle Expert software,
CILAS provides you with the ability to see the shape
of your particles along with your particle size
distribution data. Extended calculation models are
provided for the shape characterization of your
product. Images of your particles can be stored
along with particle size distribution data for later
retrieval. |
|
|
| |
| Expert report |
Our new Expert Report module was designed to
boost your productivity. It helps you create the
ultimate measurement reports. Fully customized reports
can be edited in manual or automatic mode.
Some of the functions available with Expert Report
software include the ability to export data to HTML
or Excel format, particle shape analysis, full color
graphic editing, zoom, and management of multiple
databases. |
|
|
| |
| Real time
measurement analysis |
| The Size Expert allows you to display data and
calculations in real time while measuring the particle
size distribution of your sample. Immediately see
the impact of parameter changes on the size distribution
and powder concentration. This powerful tool helps
you with protocol optimization and validation. |
|
|
| |
| ACCESSORIES
|
| CILAS offers a variety of accessories to boost
your productivity. Our accessories are compatible
with all CILAS particle size analyzers and are controlled
using The Particle Expert software. |
|
| VIDEO CAMERA
|
Visualize your samples
Add a video camera to your system to view
particle shape along with your particle size distribution
data. The video camera accessory allows you to :
- Visualize particle dispersion and agglomeration
- Analyze particle shape (d>20 µm)
- Store the images in your computer for later
analysis.
|
|
|
| |
| ALCOHOL RECIRCULATOR
|
Reduce your consumable cost
Use the alcohol recirculator when analyzing
water-soluble samples requiring alcohol or a different
carrier liquid. This accessory will recirculate
the alcohol or other carrier liquid, which will
lower your analysis and waste removal costs. Less
solvent handling will result in a safer work environment.
- Carrier liquid : Alcohol (95% or 90%) or
other liquid which requires special handling
- Totally automated operation saves time
- Optimal filtration with two different filters
- 2 to 3 stainless steel sedimentation tanks
(20 liters per tank).
|
|
|
| |
| AUTOSAMPLER
|
Increase your productivity
The autosampler will boost productivity when running
repetitive analysis. It is ideal for routine production
control, especially for high sample load applications
or test requiring reproducible results.
Main features :
- Independent methods can be programmed for
each sample
- 1 to 28 cups for samples
- Automatic cleaning of the cups
- Capable of using a dispersing agent for each
sample.
|
|
|
| |
| SMALL VOLUME UNIT |
For hard to handle materials
The small volume unit is designed for aggressive
solvents (such as acetone or benzene) or for high
cost samples (such as active products or precious
metals). Characteristics :
- Integrated mechanical stirrer and peristaltic
pump
- Totally automated operation saves time
- Sample quantities up to 50 mg
- Independent ultrasonic probe.
The small volume unit will handle solvents with
a volume from 40 to 100 ml. |
|
|