| ICP-OES Spectrometers |
| Do you need fast, accurate results in your laboratory? Want an instrument that will grow with you and your business? The JY ICP Spectrometers with their innovative design provide a tool that will increase your lab productivity not only with fast analysis time, but with less complicated methods, shorter warm-up time and better performance. |
 |
Quick and reliable results. |
 |
An instrument that is easy to understand and use. |
 |
Performance to handle difficult analyses without complex method development. |
 |
Powerful and easy to use Analyst™ software. |
 |
Comprehensive support and growth opportunity for the future through instrument upgrades and accessories. |
|
| |
|
| |
| ACTIVA-S |
 |
 |
| |
Overview
Product Overview
ACTIVA-S,
built on A Platform for the Future, maintains the Strengths of HORIBA
Jobin Yvon ICP Spectrometers while incorporating advanced CCD
technology, thus offering Simplicity in a high performance Spectrometer: - High
Scientific Spectroscopy quality CCD, adapted to the Superior Total
Plasma View, and offering the complete Spectral range of 160 – 800 nm.
- The criteria of Stability, Selectivity and Superior dynamic range, associated to Simplicity, make the difference.
- Optimum Selectivity is achieved thanks to the proprietary S3-base database.
- An
automatic Superior Semi-quantitative analysis of all elements is
performed from full Spectrum acquisition (IMAGE) and via the Total View
mode for concentration calculation, data reporting and data
reprocessing.
- Simplicity of operations with automatic
optimizations helps the user to operate the instrument at its best and
achieve excellent analytical results.
|
| Product Features
The
unique HORIBA Jobin Yvon features of low noise CCD, holographic
gratings, constant resolution across the full spectrum, superior
vertical torch-based Total Plasma View, unique sheath gas device and
low argon consumption expand the range of applications in correlation
with the large analytical benefits: - Few spectral
interference, few matrix effects, few memory effects allowing complex
matrix, high dissolved solids or organic sample analysis
- Excellent limits of quantification thanks to simultaneous measurement of background
- Perfect reproducibility, facilitating multi-user operation
- Unrivalled performance for alkaline elements
- High practical dynamic range of 107 with a linear response range of 5 decades minimum, for each line
The
ACTIVA-S offers the practical use of ICP-AES analysis by first time
operators or sophisticated users, through easy operation steps, for all
types of applications. |
 |
Specifications
Product Specifications
Generator Exhaust - Automatic solid-state, 40.68 MHz, water-cooled
Smart Hood system
Plasma - Fully demountable torch, 3 mm i.d. injector, 12 L/min plasma gas, 0.2 L/min sheath gas
Sample introduction - Concentric glass nebuliser and glass cyclone spray chamber, 3-channel peristaltic pump
Optical system - Thermo-regulated, 0.64 meter focal length, dual back-to-back gratings (4343 g/mm & 2400 g/mm with optical resolution 12 pm & 22 pm respectively), nitrogen or argon purge
Wavelength range - 160 – 800 nm
Detection - Open Electrode, 1024 x 256 pixels, 26 x 26 µm pixel size, - 30°C, 300 000 electrons as full well capacity, 1 MHz, ultra-low noise of 10 e- r.m.s. and dark current of 0.05 e-/pixel/secon |
 |
Related Products

ACTIVA-M, The Master in True Multi-line Analysis - Become an expert in quantitative ICP analysis!
ACTIVA-M,
a bronze award winner for best new product at Pittcon 2007 as Master in
multi-line analysis by ICP-AES, combines superb instrumental
performance with innovative and interactive assistance software tools. |
| |
|
| |
| ACTIVA-M |
 |
 |
|
Overview
Product Overview
ACTIVA-M,
a bronze award winner for best new product at Pittcon 2007 as Master in
multi-line analysis by ICP-AES, combines superb instrumental
performance with innovative and interactive assistance software tools:
- IMAGE
(full spectrum acquisition) & Total View mode offer a superior
semi-quantitative analysis with re-processing capabilities (as for
ACTIVA-S)
- The new proprietary ICP-based Database,
the S3-base (Single-element Spectra, Spectroscopic data) features not
only wavelengths but also ionization level, line width, limit of
detection, dynamic range of each line, thus providing data that allows
the combination of single-ele¬ment spectra to mimic real-life samples
- M.A.S.T.E.R.
(Multi-line Analysis, Selection Tool for Enhanced Reliability) performs
a selection of several appropriate lines according to the concentration
range of each element and the matrix influence
- CALSTAT helps for the evaluation of the calibration procedure through statistics on various parameters
- S.O.S.
(Statistical Outlier Survey) evaluates the line concentration results
through ANOVA data processing to detect outliers and to provide a
single reliable result per element
The
Total Multi-line Concept overcomes the challenge of multi-line
selection, copes with unexpected spectral interference and consequently
improves the reliability of the results. |
 |
Specifications
Product Specifications
Cooling - GenCo cooler for generator and coil
Exhaust - Smart Hood system
Plasma - Fully demountable torch, 3 mm i.d. injector, 12 l/min plasma gas, 0.2 l/min sheath gas
Sample introduction - Concentric glass nebuliser and glass cyclone spray chamber, 3-channel peristaltic pump
Optical system - Thermo-regulated, 0.64 meter focal length, dual back-to-back gratings (4343 g/mm & 2400 g/mm with optical resolution < 10 pm & 18 pm respectively), nitrogen or argon purge
Wavelength range - 120 – 800 nm
Detection - Back-illuminated, 2048 x 512 pixels, 13.5 x 13.5 µm pixel size, - 40°C, 100 000 electrons as full well capacity, 1 MHz, ultra-low noise of 6 e-r.m.s. and dark current of 0.025 e-/pixel/second |
 |
Related Products
ACTIVA-S, The Art in ICP Spectrometer - It’s the “S” inside that counts!ACTIVA-S,
built on A Platform for the Future, maintains the Strengths of HORIBA
Jobin Yvon ICP Spectrometers while incorporating advanced CCD
technology, thus offering Simplicity in a high performance Spectrometer. |
| |
| |
|
| |
| |
| |
| |
| ULTIMA |
 |
 |
|
| |
|
| |
| JY 2000 - 2 |
 |
| JY knows that one design does not fit all and your applications are unique to your laboratory, even if they are routine. The JY 2000 2, the second in the series of instruments defining A Platform for the Future™, offers exceptional value with pricing designed to meet even the most challenging budget. |
 |
 |
Optical design maintains the elegance and simplicity necessary to provide maximum light throughput and still provide excellent performance in resolution. |
 |
New sample introduction area with a focus on productivity. |
 |
No other ICP spectrometer today offers better performance than the JY 2000 2 except the ULTIMA 2! Typical detection limit for Pb is 5 ppb on a radial view plasma. Radial view minimizes interferences. |
 |
Continuous wavelength coverage from 160 to 800nm as a standard with optional extension to 120nm for VUV analysis of the halogen elements or the use of alternative wavelengths. |
|
| |
|
| |
| ULTIMA 2Series |
 |
| The ULTIMA 2C Series of Combination ICP spectrometers offers the ultimate in performance from the ULTIMA 2 combined with the highest level of sample throughput. The series offers two models to suit an extensive range of applications and budgets. |
 |
| ULTIMA 2C |
- Combination of the ULTIMA 2 with 0.5m simultaneous optics.
- High performance for a wide range of sample types.
|
|
| ULTIMA 2CE |
- Optimized for environmental applications.
- US EPA CLP analysis in less than 4 minutes (download reprint).
|
|
| ULTIMA 2C HR |
- Combination of the ULTIMA 2 with 1.0m simultaneous optics.
- Greater performance in resolution and sensitivity.
- Top-of-the-line in ICP OES instrumentation.
- Excellent for complex materials such as W, Zr, U, precious metals or rare earth elements in trace concentrations.